Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Clinical and Radiographic Evaluation of Short Locking-Taper Implants Supporting Single Crowns in the Posterior Region: A 12-Year Retrospective Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Ahead of Print


Clinical and Radiographic Evaluation of Short Locking-Taper Implants Supporting Single Crowns in the Posterior Region: A 12-Year Retrospective Study

Yilin Liao/Xinyu Wu/Yaoyu Zhao/Qi Yan/Bin Shi


PMID: 37338924
DOI: 10.11607/prd.6031

Few studies have reported the outcomes of short implants with a follow-up time longer than 10 years. This retrospective study aimed to evaluate the long-term outcomes of the short locking-taper implants supporting single crowns in the posterior region. Patients who received short locking-taper implants (≤ 8 mm) supporting single crowns in the posterior region from 2008 to 2010 were included. The clinical outcomes, radiographic outcomes, and patient satisfaction were recorded. As a result, a total of 18 patients with 34 implants were included. The cumulative survival rate was 91.4% and 83.3% at implant level and patient level, respectively. Tooth brush habit and history of periodontitis were significantly associated with implant failure (P < .05). The median marginal bone loss (MBL) was 0.24 mm (interquartile range: 0.01 to 0.98). Biologic and technical complications occurred in 14.7% and 17.8% implants, respectively. The mean modified sulcus bleeding index and mean peri-implant probing depths were 0.52 ± 0.63 and 2.38 ± 0.79 mm, respectively. All patients were at least quite satisfied, with the majority of patients being fully satisfied (88.9%) with the treatment. Within the limitations of this study, the short locking-taper implants supporting single crowns in the posterior region achieved promising outcomes in the long-term follow-up.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help